多介質(zhì)過(guò)濾器反洗操作步驟
保證水源→開(kāi)1#多介質(zhì)過(guò)濾器排氣閥→開(kāi)1#多介質(zhì)正洗進(jìn)→開(kāi)1#多介質(zhì)正洗出一開(kāi)
1#活性炭排氣閥→開(kāi)1#活性炭正洗進(jìn)→開(kāi)1#活性炭正洗出一開(kāi)反滲透進(jìn)水閥一
開(kāi)濃排閥→開(kāi)生水泵→開(kāi)阻垢劑 →開(kāi)殺菌劑 →開(kāi)絮凝劑 →開(kāi)助凝劑 →啟動(dòng)
高壓泵一關(guān)1#多介質(zhì)排氣一關(guān)1#活性炭排氣閥一待濃排閥排5至10分鐘后關(guān)
閉濃排閥→開(kāi)1#風(fēng)機→開(kāi)1#混床排氣閥→開(kāi)1#混床正洗進(jìn)→開(kāi)1#混床下排-
開(kāi)1#中間水泵一關(guān)1#混床排氣閥一待混床排電導率小于1us/cm 時(shí)開(kāi)1#混床正
洗出→關(guān)閉下排送水
關(guān)閉流程:
開(kāi)濃排閥一停中間水泵一開(kāi)1#多介質(zhì)排氣閥→開(kāi)1#活性炭排氣閥→停高壓泵一
停生水泵→停阻垢劑→停殺菌劑→停絮凝劑→停助凝劑 →關(guān)1#多介質(zhì)正洗進(jìn)
→關(guān)1#多介質(zhì)正洗出→關(guān) 1#多介質(zhì)排氣閥→關(guān)1#活性炭正洗進(jìn)→關(guān)1#活性炭
- 上一篇:多介質(zhì)過(guò)濾器反沖洗工作原理 2024/6/25